TRL CMNS
FURMATS offer Burnt Magnesia-Chrome Brick including TRL CMNS for Back up lining of ladle, AOD ,LD Converter and Non-ferrous Industry
PRODUCT DESCRIPTION
Burnt Magnesia-Chrome Brick
APPLICATION
Back up lining of ladle, AOD ,LD Converter and Non-ferrous Industry
CONTROL PROPERTIES
CONTROL PROPERTIES | ||||
CHEMICAL ANALYSIS (Calcined Basis) | UNIT by wt. | VALUE | TEST METHOD | |
Typical | Limit | |||
Cr2O3 | % | 14.7 | ≥ 10.0 | |
MgO | % | 45.1 | ≥ 40.0 | By XRF |
PHYSICAL PROPERTIES | UNIT | VALUE | TEST METHOD | |
Typical | Limit | |||
Bulk Density | gm/cc | 2.8 | ISO 5017: 1998 | |
App. porosity | Vol.% | 19.8 | ≤ 22.0 | ISO 5017: 1998 |
CCS | kg/cm2 | 365 | ≥ 300 | ISO 10059-2:2003 |
RUL (ta) at 2 kg/cm2 | oC | 1630 | ≥ 1600 | IS 1528- Part 2 |
SUPPLEMENTARY PROPERTIES (FOR INFORMATION ONLY) | ||||
PLC at 1600°C/2hrs | % | 0.12 | – | ISO 2478:1987 |
Control Dimensions | AQL 6.5% for critical dimensions (ISO 5022) | |||
Shelf Life | 12 months from the date of manufacture when stored under shed and free from moisture |
Note: 1) The typical technical data shown are based on average results on production samples and are subjected to normal variation on individual tests. Hence, it cannot be taken as specification.
2) The above specification is valid for solid pressed standard items only. For shaped items and weight more than 20Kg may have a variation of 10%.
Disposal Consideration: May be disposed in an approved landfill unless contaminated in service. If contaminated with hazardous materials, place waste in suitable container. Seal and properly label the waste container. Send the container to an approved Transportation, Storage and Disposal (TDS) facility via an approved waste hauler. Be sure manifests have been completed and an adequate “Paper trial” has been established.